VCL-SAFECOMM-E-FE-DIN
Automatic Ethernet Failover / AB / Fallback Switch
VCL-SafeComm-E is a family of Ethernet Failover Protection Switches that provide 1+1 Automatic Ethernet Failover / AB Fallback Protection between an "active” and "standby" equipment; or between “main” and “standby” networks which are connected to the network through an Ethernet interface.
VCL-SafeComm-E-FE-DIN - 10/100BaseT Fast Ethernet Failover (Compact DIN-Rail) unit which supports a maximum of 100MBits/sec. data throughput on its primary and standby interfaces. The unit is powered from a 12VDC power source with the option of an external AC-DC adapter.
Number of interfaces available in Fast Ethernet version: Three
- 1 x 10/100 Fast Ethernet Interface: Network A (Primary)
- 1 x 10/100 Fast Ethernet Interface: Network B (Standby)
- 1 x 10/100 Fast Ethernet Interface User (Protected)
1+1 AC or DC power supply available in 19 Inch Rack Mount version.
Use Case # 1: The VCL-SafeComm-E, Ethernet Failover equipment provides 1+1 Automatic Ethernet Failover Switching / Fallback Protection between two, Main and Standby Switches, Servers, RTUs or any other similar terminals to provide equipment redundancy in applications which require 99.99% terminal equipment up-time. The Ethernet 1+1 fail-over protection automatically switches to the “standby” terminal equipment in the event of failure of the “primary” terminal equipment to ensure that the 99.99% terminal equipment up- time requirements are always being met.
Use Case # 2: The VCL-SafeComm-E, Ethernet Failover equipment provides 1+1 Automatic Ethernet Failover / AB Fallback Switch provides protection between an "active” and "standby" IP / Ethernet / MPLS Networks (including "active” and "standby" Gateways and Routers) to provide 1+1 automatic Ethernet fail-over protection between two distinctly separate networks through an Ethernet interface.
Features and Benefits
- Fail-Safe. Never becomes a point of failure. Automatically reverts to and reconnects to the “primary network” / even in a power down condition.
- End-to-End network Link monitoring
- User configurable link test parameters.
- User configurable switching parameters.
- Built-in real-time clock (RTC) / real-time logging maintains a history of all events.
- Serial Management Interface (USB) for local access.
- Remote access over TCP-IP networks. Allows the user to access and carry out maintenance, or / and switch the links remotely, if required
- Password Controlled Access. Maintains a complete log of all logins.
- Script Assisted Switching. Automatically initiates switching upon receipt of the scripted message / SNMP Trap.
- Switching initiated through external triggers such as “Dry Contact Alarm Relays”.
- Manual Switching through front-panel buttons automatic front panel locking to prevent accidental switching.
- Enhances network availability and reliability.
- Eliminates network downtime by automatically / seamlessly switch to the "backup” / “standby" network in the event of the complete and total failure of the primary/ active IP network.
- Disaster Recovery. To provide automatic failover protection in mission critical applications requiring minimum downtime.
- To switch between and automatically re-route IP traffic to the “standby” terminal equipment upon the failure of the “primary” terminal equipment.
- Alerts the user upon the failure ot unavailability of any one of the two “active” / “primary” or "secondary”/“standby" terminal equipment .
- Automatic Test Feature. Concurrently tests both “active” and “standby” equipment,, for “end-to-end” link and terminal equipment availability.
- VCL-Safecomm-E-FE-DIN may be used to provide automatic fail-over protection and switching between two terminal equipments such as Routers, Servers, Gateways, RTUs, SCADA Servers, Railway Signaling Equipment, Data Terminal equipment (any type of Ethernet device) etc...
To provide 1+1 Terminal / Equipment Failover Protection.
Ethernet link is connected to NRouters, Servers, Switches, RTUs, Data Terminals (any terminal) etc.
Equipment 1 fails. Ethernet link automatically switches to Routers, Servers, Switches, RTUs, Data Terminals (any terminal) etc.
Equipment 1 recovers. Ethernet link automatically reverts and reconnects to Routers, Servers, Switches, RTUs, Data Terminals (any terminal) etc.
Specifications | |
Number of Ethernet | 3 |
Interfaces |
|
Guaranteed Maximum Data Throughput | 100Mbps |
Interface Type | 10/100BaseT |
Conformity | IEEE-802.3 |
Management and Control Ports | |
Serial Management Port - RS232 COM Port and USB Port | |
10/100 BaseT for remote management | |
NMS (with Telnet) Specifications | |
OAM Network Interface | RJ-45 Ethernet, 10/100BaseT |
Compatibility | Ethernet Version 2.0 IEEE802.3 |
Input Voltage reversal Protection | Provided in the system |
Monitoring and Management | Serial login, Telnet, SSH (with option to disable clear text for users) |
AC Power Supply Specifications | |
Range of input AC | 100~240VAC, 50/60Hz |
DC Power Supply Specifications | |
Input DC voltage | 12VDC (nominal) |
Range of input voltage | 9 to 14 VDC Input |
Input voltage reversal Protection | Provided |
Short Circuit Protection | Provided |
110VDC~220VDC Power Supply Specifications | |
Input DC voltage - Dual Input | 110VDC; or 220VDC (nominal) |
Range of input voltage | 85VDC to 290VDC |
Input voltage reversal Protection | Provided |
Short Circuit Protection | Provided |
Core Unit without PSUs
VCL-SafeComm-FE-DIN
Automatic Ethernet Failover Switch
- Provides 1+1 Automatic Ethernet Failover Protection between two (Main and Standby) Ethernet Switches, Gateways, Terminals, Servers, Routers, RTUs, etc
- DIN Rail version
Supports:
- 3 x Ethernet [100Mbps RJ45 (F)] [1 for Network A, 1 for Network B, 1 for User]
- Management: Telnet (RJ45 (F) Port), Serial Port (USB), EMS, Graphical User Interface (GUI)
- Installation Kit: System Core Cables, Mounting Hardware, Documentation, User Manual