VCL-SAFECOMM-E-FE-DIN

Automatic Ethernet Failover / AB / Fallback Switch

VCL-SafeComm-E is a family of Ethernet Failover Protection Switches that provide 1+1 Automatic Ethernet Failover / AB Fallback Protection between an "active” and "standby" equipment; or between “main” and “standby” networks which are connected to the network through an Ethernet interface.

VCL-SafeComm-E-FE-DIN - 10/100BaseT Fast Ethernet Failover (Compact DIN-Rail) unit which supports a maximum of 100MBits/sec. data throughput on its primary and standby interfaces. The unit is powered from a 12VDC power source with the option of an external AC-DC adapter. 

Number of interfaces available in Fast Ethernet version: Three

  • 1 x 10/100 Fast Ethernet Interface: Network A (Primary)
  • 1 x 10/100 Fast Ethernet Interface: Network B (Standby)
  • 1 x 10/100 Fast Ethernet Interface User (Protected)

1+1 AC or DC power supply available in 19 Inch Rack Mount version.

Use Case # 1: The VCL-SafeComm-E, Ethernet Failover equipment provides 1+1 Automatic Ethernet Failover Switching / Fallback Protection between two, Main and Standby Switches, Servers, RTUs or any other similar terminals to provide equipment redundancy in applications which require 99.99% terminal equipment up-time. The Ethernet 1+1 fail-over protection automatically switches to the “standby” terminal equipment in the event of failure of the “primary” terminal equipment to ensure that the 99.99% terminal equipment up- time requirements are always being met.

Use Case # 2: The VCL-SafeComm-E, Ethernet Failover equipment provides 1+1 Automatic Ethernet Failover / AB Fallback Switch provides protection between an "active” and "standby" IP / Ethernet / MPLS Networks (including "active” and "standby" Gateways and Routers) to provide 1+1 automatic Ethernet fail-over protection between two distinctly separate networks through an Ethernet interface.

Features and Benefits

  • Fail-Safe. Never becomes a point of failure. Automatically reverts to and reconnects to the “primary network” / even in a power down condition.
  • End-to-End network Link monitoring
  • User configurable link test parameters.
  • User configurable switching parameters.
  • Built-in real-time clock (RTC) / real-time logging maintains a history of all events.
  • Serial Management Interface (USB) for local access.
  • Remote access over TCP-IP networks. Allows the user to access and carry out maintenance, or / and switch the links remotely, if required
  • Password Controlled Access. Maintains a complete log of all logins.
  • Script Assisted Switching. Automatically initiates switching upon receipt of the scripted message / SNMP Trap.
  • Switching initiated through external triggers such as “Dry Contact Alarm Relays”.
  • Manual Switching through front-panel buttons automatic front panel locking to prevent accidental switching.

 



  • Enhances network availability and reliability.
  • Eliminates network downtime by automatically / seamlessly switch to the "backup” / “standby" network in the event of the complete and total failure of the primary/ active IP network.
  • Disaster Recovery. To provide automatic failover protection in mission critical applications requiring minimum downtime.
  • To switch between and automatically re-route IP traffic to the “standby” terminal equipment upon the failure of the “primary” terminal equipment.
  • Alerts the user upon the failure ot unavailability of any one of the two “active” / “primary” or "secondary”/“standby" terminal equipment .
  • Automatic Test Feature. Concurrently tests both “active” and “standby” equipment,, for “end-to-end” link and terminal equipment availability.
  • VCL-Safecomm-E-FE-DIN may be used to provide automatic fail-over protection and switching between two terminal equipments such as Routers, Servers, Gateways, RTUs, SCADA Servers, Railway Signaling Equipment, Data Terminal equipment (any type of Ethernet device) etc...

To provide 1+1 Terminal / Equipment Failover Protection.

Ethernet link is connected to NRouters, Servers, Switches, RTUs, Data Terminals (any terminal) etc.

Equipment 1 fails. Ethernet link automatically switches to Routers, Servers, Switches, RTUs, Data Terminals (any terminal) etc.

Equipment 1 recovers. Ethernet link automatically reverts and reconnects to Routers, Servers, Switches, RTUs, Data Terminals (any terminal) etc.

 

Specifications

Number of Ethernet

3

Interfaces

  • 1x 10/100 Ethernet Interface: Network A (Primary)
  • 1 x 10/100 Ethernet Interface: Network B (Standby)
  • 1x10/100 Ethernet Interface User (Protected)

Guaranteed Maximum Data Throughput

100Mbps

Interface Type

10/100BaseT

Conformity

IEEE-802.3

Management and Control Ports

Serial Management Port - RS232 COM Port and USB Port

10/100 BaseT for remote management

NMS (with Telnet) Specifications

OAM Network Interface

RJ-45 Ethernet, 10/100BaseT

Compatibility

Ethernet Version 2.0 IEEE802.3

Input Voltage reversal Protection

Provided in the system

Monitoring and Management

Serial login, Telnet, SSH (with option to disable clear text for users)

AC Power Supply Specifications

Range of input AC

100~240VAC, 50/60Hz

DC Power Supply Specifications

Input DC voltage

12VDC (nominal)

Range of input voltage

9 to 14 VDC Input

Input voltage reversal Protection

Provided

Short Circuit Protection

Provided

110VDC~220VDC Power Supply Specifications

Input DC voltage - Dual Input

110VDC; or 220VDC (nominal)

Range of input voltage

85VDC to 290VDC

Input voltage reversal Protection

Provided

Short Circuit Protection

Provided

Core Unit without PSUs

VCL-SafeComm-FE-DIN

Automatic Ethernet Failover Switch

  • Provides 1+1 Automatic Ethernet Failover Protection between two (Main and Standby) Ethernet Switches, Gateways, Terminals, Servers, Routers, RTUs, etc
  • DIN Rail version

Supports:

  • 3 x Ethernet [100Mbps RJ45 (F)] [1 for Network A, 1 for Network B, 1 for User]
  • Management: Telnet (RJ45 (F) Port), Serial Port (USB), EMS, Graphical User Interface (GUI)
  • Installation Kit: System Core Cables, Mounting Hardware, Documentation, User Manual